Glossary
Navigation
What the words on SewersOnline’s screens and reports mean, as the app uses them. For the rules behind a term, open the help page named in the right-hand column.
People and records
| Term | Meaning | See |
|---|---|---|
| Persona | A saved set of your branding (letterhead, signature, sign-off) and the defaults and preferences for new designs. You always have a Default persona; each design picks one on its first page. | Personas, Design Wizard: Persona |
| Permittee | The property owner or permit applicant the design is for. | Client - Permittee |
| SEO | Sewage Enforcement Officer: the local official who reviews the site tests and issues the permit. | Permitting Agency |
| Permitting agency | The county, township or other authority that enforces the sewage rules where the site is. | Permitting Agency |
| Serial number (SN) | The 8-digit number a design gets when it is first saved. | Design Navigator |
Site data
| Term | Meaning | See |
|---|---|---|
| Perc (percolation) rate | How fast water soaks into the soil in the site’s percolation tests, in minutes per inch. | Site Investigation |
| HLLR | Hydraulic linear loading rate: how much effluent may be applied per linear foot of bed edge, taken from a soil scientist’s report. The Hydraulic Linear Loading Rate Method uses it, with the infiltration loading rate, instead of perc data. | Site Investigation |
| Limit zone | The soil layer that limits treatment, such as rock or seasonal high water. The app asks for the depth to limit zone in inches. | Site Investigation |
| Critical data | Values such as the perc rate, limit zone, slope, HLLR and sizing method. Changing one on a design that has already been printed means the design must be purchased again. | Site Investigation, Finish |
Guidance
| Term | Meaning | See |
|---|---|---|
| Standard guidance | Systems and rules that apply without special justification. | System Type |
| Alternate / Experimental guidance | Systems the rules allow under alternate or experimental listings; the wizard asks for a justification. | System Type |
| BTG | Best Technical Guidance. In the app it is for repairs only: checking invoke BTG on Site Investigation relaxes some limits and requires a justification on System Type. | Site Investigation, System Type |
| Justification | The text you type on System Type to support a non-standard choice. It prints in the report. | System Type |
System parts
| Term | Meaning | See |
|---|---|---|
| Primary treatment | The first tank: septic, combination (combo) or aerobic. | System Type, Tank Selection |
| Secondary treatment | An optional filter after the primary tank, such as Ecoflo, Puraflo, AdvanTex, a free-access sand filter (FASF), or a buried or recirculating sand filter. | System Type |
| Buried sand filter | A sand filter buried below grade and pressure dosed by a pump on a timer (SFTF Manual §25.1). In the app it follows an aerobic tank on a residential stream discharge. It is sized at the largest of the hydraulic loading (1.0 gpd/ft²), the organic loading (5 lb BOD₅ per 1,000 ft² a day) and 300 ft². | System Type, Dosing to Filter |
| Recirculating sand filter (SFTF) | A sand filter that is dosed many times a day, with part of its effluent sent back through it (SFTF Manual §25.2). In the app it follows an aerobic tank on a residential stream discharge. It is sized at the largest of the hydraulic loading (3.0 gpd/ft²), the organic loading (5 lb BOD₅ per 1,000 ft² a day) and 150 ft², and dosed 48 times a day. | System Type, Dosing to Filter |
| SFTF Manual | DEP’s Small Flow Treatment Facilities Manual (385-2188-005). It sets the rules for stream-discharge systems, including the sand filters above. | System Type |
| Disinfection | Treatment before a stream discharge: ultraviolet light or chlorination. | Disinfect |
| Discharge (absorption area) | Where the treated effluent goes: bed, trench, elevated sand mound, at-grade, Eljen GSF, drip, stream and so on. | System Type |
| Dosing | Sending effluent to the absorption area in measured doses instead of letting it trickle. Dosing uses a pump or a siphon in a dosing tank. | Dosing to Discharge |
| Siphon | A device with no moving parts or power that empties a dosing tank once it fills to a set level. The wizard chooses one when the bed is far enough below the tank. | Siphon Selection |
| Drawdown | How far the liquid level in a dosing tank drops during one dose. | Siphon Selection, Dosing Pump |
| Delivery line | The pipe from the dosing tank to the absorption area’s manifold. | Plumbing pages |
| Manifold | The pipe that splits the delivery line into the laterals. It is fed from the end or the center. | Manifold, Plumbing pages |
| Lateral | A perforated distribution pipe running along the absorption area. | Plumbing pages |
| Head | Pressure expressed as feet of water. A pump or siphon must supply enough head to push the dose to the end of the laterals. | Dosing Pump |
| Spec sheet | A manufacturer’s product sheet. The Design PDF lists the ones for your chosen parts in an index and appends them at the end. | Finish |
Design status
| Term | Meaning | See |
|---|---|---|
| Purchased / enabled | A design whose license fee is paid. Only these produce PDFs. | Purchasing, Finish |
| Printed | A purchased design whose Design PDF has been built. Changing critical data afterwards disables it until it is re-purchased. | Finish |
| Borrow (copy to new…) | Start a new design from an existing one. It keeps the site data, system choices and header (client, agency, billing and mailing), but not the serial number, dates, license or plot plan. | Design Navigator |