Manifold

Choose where the manifold attaches along the Eljen GSF mound.

When you see this page

The page appears only for Eljen GSF Mound designs, right after System Type. Other systems don’t show it and use a center manifold.

Manifold Position

The question on the page is Where does the manifold attach to the distribution box? (from the down-slope perspective)

Option Meaning
Left at the left end
Center at the middle
Right at the right end

Center is selected if the design has no position yet. The page has no validation.

What it affects

  • The module layout, lateral layout and manifold text in the report.
  • The Plumbing page: Connect laterals with (crosses or double tees) appears only on a center manifold.
  • The manifold fittings and the head. A Left or Right manifold has a tee at each lateral but the last and a 90° elbow at the last lateral. If the delivery line joins it between laterals, it has two ends: a tee at each lateral but the two end ones, and a 90° elbow at each end. The elbows are listed in the materials and in the Discharge Fitting Allowances, and they add to the total head. A Center manifold is unchanged.

System Type, Discharge Pump Plumbing, Absorption Area Adjustments.