Dosing To Filter

Enter how the dosing tank sits relative to the treatment filter, along both the pumped line and the return line.

When you see this page

The page appears when the secondary treatment is a Puraflo biofilter, a Buried Sand Filter or a Recirculating Sand Filter (SFTF). A pump timed-doses all of them. The card is titled Dosing Tank to Filter. Filter Pump Plumbing and Dosing Pump:To Filter follow it.

Buried and recirculating sand filters: the filter drains to disinfection, not back to the dosing tank, so Distance filter to dosing tank is hidden and not checked. The note about the outflow being gravity driven still shows; you can ignore it for these filters. The elevation and distance you enter here set the filter’s dosing head in the report.

Fields

Field Unit
Elevation change tank to filter, with ↑ up / ↓ down ft
Distance tank to filter (min 2) ft
Extra depth of tank (0 to 10) ft
Distance filter to dosing tank (min 2) ft
  • Elevation change tank to filter: the change in ground level from the dosing tank to the filter. Enter the size of the change and click ↑ up or ↓ down.
  • Distance tank to filter: the pumped line, measured along the pipe route.
  • Extra depth of tank: how much deeper than normal the dosing tank is buried.
  • Distance filter to dosing tank: the gravity return line.

The page notes: Outflow from filter is gravity driven, so it is assumed the dosing tank is suitably downhill from the filter.

Messages

  • Tank is too close to filter (minimum 2 ft).
  • Filter is too close to dosing tank (minimum 2 ft).
  • Too much drop for a pump (by X ft). Move the tank closer to the filter or sink it deeper.

Tips

  • Both distances set the coupling counts on Filter Pump Plumbing. Changing either one resets that page’s counts to the defaults.
  • The return line runs by gravity, so it needs no pump sizing.

System Type, Filter Pump Plumbing, Dosing Pump, Tank Selection.