Filter Pump Plumbing
Navigation
Enter the fitting counts for the pumped line to the treatment filter and for the gravity line back to the dosing tank.
When you see this page
The page appears when the secondary treatment is a Puraflo biofilter, a Buried Sand Filter or a Recirculating Sand Filter (SFTF). A pump timed-doses all of them. It follows Dosing to Filter and comes before Dosing Pump:To Filter.
The page has two parts, one for each run. For a buried or recirculating sand filter, only the pump-to-filter part shows: the filter drains to disinfection, so there is no return line to the dosing tank.
Pump to filter fittings allowances
The inflow line is 2" in diameter. The page notes that the tees and one 90° elbow form the supply manifold, and one elbow is used to exit the dosing tank.
| Field | Default |
|---|---|
| 90° Elbows (min 2) | 2 |
| 45° Elbows | 3 |
| Couplings | (distance ÷ 10) − 1, rounded down |
One quick disconnect is added automatically.
Filter to dosing tank fittings allowances
The outflow line is 4" in diameter. One tee is a sampling port, and the other tees and one 90° elbow form the outflow manifold.
| Field | Default |
|---|---|
| 90° Elbows (min 1) | 1 |
| 45° Elbows | 2 |
| Couplings | (distance ÷ 10) − 1, rounded down |
The couplings use the distances you entered on Dosing to Filter: Distance tank to filter and Distance filter to dosing tank.
Keeping your entries
If you come back and neither distance nor the persona has changed, your counts are kept. If either distance or the persona changed, every field returns to its default.
Tips
- Both diameters are fixed by the filter design and can’t be changed.
- The return line runs by gravity, so its fittings add no pump head.
- The hole size and delivery line diameter belong to the absorption area, so this page doesn’t show them. Set them on Discharge Pump Plumbing or Siphon Plumbing. Passing through this page leaves them unchanged.
Related pages
Dosing to Filter, Dosing Pump, Tank Selection.